METHOD 9 – VISUAL DETERMINATION OF THE OPACITY OF EMISSIONS FROM. STATIONARY SOURCES. Many stationary sources discharge visible emissions into the atmosphere; these emissions are usually in the shape of a plume. This method involves the determination of plume opacity by qualified observers.
What is the standard duration of a Method9 test?
Visual determination of emissions opacity must be performed in accordance with the procedures of EPA Method 9, of 40 CFR part 60, Appendix A-4, and while the affected source is operating under normal conditions. The duration of the EPA Method 9 test shall be thirty minutes.
How close should an observer stand to the emission source?
The method recommends that you stand no closer than 15 feet and no farther away than ¼ mile from the source you want to observe. Pick a spot where the sunlight is not shining directly into your eyes.
How long is a Method 9 certification valid?
6 months
The legal validity of emissions observations is dependent upon adherence to the regulations and guidelines set forth in Federal Reference US EPA Method 9. These regulations apply to smoke school providers as well as trained observers. Field certification is valid for 183 days (6 months).
How does an opacity monitor work?
Dynoptic opacity monitors use the light transmission technique to measure the visible opacity of exhaust gas in a duct, stack or flue, in which a high intensity light beam is projected across the stack.
What is opacity in air quality?
With regards to stack emissions, opacity is the degree to which visibility of a background (i.e., blue sky) is reduced by particulates (smoke). The EPA Method 9 Opacity Observation Form, provided in Appendix A, is the enforceable monitoring record which evaluates the quantitative 20% opacity limit.
What is a Method 9?
Method 9 – Visual Determination of the Opacity of Emissions From Stationary Sources. Many stationary sources discharge visible emissions into the atmosphere; these emissions are usually in the shape of a plume. This method involves the determination of plume opacity by qualified observers.
How do you measure opacity?
What is Opacity? Opacity is that property of a substrate that resists the passage of light. This is calculated by measuring the percentage of the light which is absorbed by a sheet of paper.
How do you measure opacity of a liquid?
Opaque Liquids are impenetrable by light and are best measured using Directional 45/0° reflectance geometry. This is the geometry that most closely matches how the human eye ‘sees’ color.
What does an opacity meter measure?
Introduction. Smoke and smoke opacity meters are instruments measuring the optical properties of diesel exhaust. These instruments have been designed to quantify the visible black smoke emission utilizing such physical phenomena as the extinction of a light beam by scattering and absorption.
How is paint opacity measured?
Opacity (%) is simply the Contrast Ratio multiplied by 100 to get a percentage, where 100% is complete hiding. The test method consists of spreading the paint over a Leneta Chart (paper with Black & White strip) and measuring the reflectance of the dried paint film in the white (Rw) and black areas (Rb).
What does EPA method 22 do for emissions?
EPA Method 22 is a test method for demonstrating compliance from fugitive sources and from flares. It is not an alternative method to EPA Method 9. Instead of determining the opacity of emissions, EPA Method 22 determines the frequency of visible emissions.
When did EPA revise method 9 opacity evaluation?
EPA conducted extensive field studies on the accuracy and reliability of the Method 9 opacity evaluation tech- nique when the method was revised and repromulgated in response to industry challenges concerning certain NSPS opacity standards and methods.
What is the CFR method 9 visual opacity test?
CFR Promulgated Test Method 9 Visual determination of the opacity of emissions from stationary sources. Contact Us to ask a question, provide feedback, or report a problem.
How is the opacity of visible emissions determined?
For example, some SIP opacity rules limit visible emissions to a speci- fied number of minutes per hour or other time period (time exemption); some limit opacity to a cenain level averaged over a specified number of minutes (time aver- aged); some set opacity. limits where no single reading can exceed the standard (instantanous or “cap”).